A transformer has 400 turns and 200 turns in the primary and secondary windings respectively. If the current in the primary and secondary windings are 3A and 5A respectively. calculate the efficiency of the transformer?

a

85.0%

b

83.3%

c

37.5%

d

30.0%

Download Offline App Ask a Question

Explanation

Correct Option
b

No explanation available

Video Explanation

No video available

Post your Contribution

Share:

Discussions (5)

adurajohn
6 years ago
Image

Thank you for the opportunity.

Dodobae12
3 years ago

[Is*Ns/ Ip*Np]*100= [200*5/ 400*3]*100
= [1000/1200]*100
=0.8333*100
=83.33%


I hope this was explanatory and helpful๐Ÿ˜‡